| Technical data | BM15 | BM20 | BM30 | T500 | T600 | T650 |
| Article no. |
3.510.205.020 |
3.510.205.021 |
3.510.205.030 |
3.510.207.500 |
ZB9110012 |
ZB9110014 |
Display
sensor 1 |
Measured value |
Wood moisture / Material moisture |
Wood moisture / Material moisture |
Material moisture / Surface moisture |
Wood moisture / Material moisture |
Material moisture / Sub-surface moisture |
Material moisture / Surface moisture |
| Units |
% |
% |
Digit |
%, Digit |
Digit |
Digit |
Display
sensor 2 |
Measured value |
|
|
|
Compensation value for wood temperature * |
|
|
| Units |
|
|
|
°C, °F |
|
|
Material
moisture |
Measuring principle |
Resistance
method |
Resistance
method |
Dielectric |
Resistance
method |
Microwave |
Dielectric |
| Measuring range |
0.2 - 2.0 % |
0.2 - 2.4 % |
0 to 100 digit |
15 to 100 digit |
0 to 200 digit |
0 to 200 digit |
| Resolution / Accuracy |
approx. ± 0.05 % |
approx. ± 0.05 % |
1 digit / – |
0.1 digit / 0.1 digit |
|
|
| Depth of penetration |
N.S. |
N.S. |
5 to 40 mm |
approx. 10 mm ** (connection) |
Max. 300 mm (non-destructive) |
Max. 40 mm (non-destructive) |
| Wood moisture |
Measuring principle |
Resistance
method |
Resistance
method |
|
Resistance
method |
|
|
| Measuring range |
6 - 44 % |
1 - 45 % |
|
5 % to 50 % |
|
|
| Resolution / Accuracy |
approx. ± 1 % |
approx. ± 1 % |
|
0.1 % / 1 % *** |
|
|
Temperature
compensation |
|
|
|
0 °C to 50 °C |
|
|
Electrodes
length / ø |
approx. 8 mm
/ 2.2 mm |
approx. 8 mm
/ 2.2 mm |
|
20 mm / 1.5 mm |
|
|
| Max. depth of penetration |
N.S. |
N.S. |
|
approx. 10 mm 4) |
|
|
| Functions |
Alarm signal |
|
|
|
|
Audible |
Audible |
| Menu functions |
Battery status and function check |
Battery status and function check, selection slide to change modes |
Minimum, maximum value display, hold function, backlit display, auto |
Hold, Sens, Mat., Temp., Unit 2 |
Max., Min., Hold, Alarm |
Max., Min., Hold, Alarm |
| General tech. data |
Dimensions approx. |
130 x 40 x 25 mm |
139 x 47 x 25 mm |
180 x 45 x 35 mm |
168 x 48 x 25 mm |
180 x 65 x 65 mm |
190 x 48 x 25 mm |
| Weight approx. |
100 g |
100 g |
180 g |
320 g |
220 g |
250 g |
Operation
conditions**** |
0 to 40 °C,
< 85 % R.H. |
0 to 40 °C,
< 85 % R.H. |
0 to 40 °C,
< 85 % R.H. |
0 to 50 °C,
< 90 % R.H. |
-10 to 60 °C,
< 95 % R.H. |
0 to 50 °C,
< 95 % R.H. |
Storage
conditions**** |
0 to 40 °C,
< 85 % R.H. |
0 to 40 °C,
< 85 % R.H. |
0 to 40 °C,
< 85 % R.H. |
-10 to 60 °C,
< 95 % R.H. |
-30 to 60 °C,
< 95 % R.H. |
-30 to 60 °C,
< 95 % R.H. |
| * only in the wood moisture measuring mode; ** with standard electrodes *** in the range of 6 % to 30 % wood moisture; **** not condensing |