| Technical data | ID 500 | ID 800 |
|---|---|---|
| Article no. | 1.430.001.100 | 1.430.001.150 |
| Air flow rate | 7,350 m³/h | 10,100 m³/h |
| Air pressure max. | 220 Pa | 290 Pa |
| Fan | axial | High-pressure axial |
| Rated heat input max. | 121 kW | 167 kW |
| Heating capacity | 110 kW (94,600 kcal) | 154 kW (132,416 kcal) |
| Temperature increase* ΔT | 52 °C | 54 °C |
| Input voltage | 230 V / 50 Hz | 230 V / 50 Hz |
| Current consumption | 6.0 A | 10.5 A |
| Fuel consumption max. | 11.8 l / h | 16.5 l / h |
| Outlet cone | 500 mm | 500 mm |
| Chimney connection | 200 mm | 200 mm |
| Thermostat connection | standard | standard |
| Sound level (distance 1 m) | 74 dB (A) | 78 dB (A) |
| Dimensions L x W x H | 2,100 x 920 x 1,350 mm | 2,400 x 800 x 1,250 mm |
| Weight (with blower oil burner) | 312 kg | 460 kg |
| *ΔT designates the increase in temperature. The air discharge temperature is calculated using ΔT + ambient air temperature. Calculation example for ID-500 oil heating units with an ambient temperature of 20 °C: ΔT (52) + 20 = 72. The air discharge temperature in this example equals 72 °C. |
||