Technical data heater units

Technical data ID 1000 ID 1200 ID 2000
Air flow rate max. Stage 1 9,120 m³ 9,780 m³ 25.100 m³
Stage 2 * 12,950 m³ 13,860 m³
Air pressure max. Stage 1 480 Pa 540 Pa 300 Pa
Stage 2 * 540 Pa 620 Pa
Fan High-pressure radial High-pressure radial High-pressure radial
Rated heat input max. Stage 1 150 kW 160 kW 375 kW
Stage 2 * 200 kW 220 kW
Heating capacity max. Stage 1 138 kW (118,659 kcal) 148 kW (127,257 kcal) 345 kW (296,647 kcal)
Stage 2 * 184 kW (158,240 kcal) 203 kW (174,548 kcal)
Sound level (distance 1 m) ** 74 dB (A) 74 dB (A) 75 dB (A)
Temperature increase*** ∆T 57 °C 59 °C 55 °C
Input voltage 400 V / 50 Hz 400 V / 50 Hz 400 V / 50 Hz
Current consumption max. Stage 1 NS NS 29.5 A
Stage 2 * 9.3 A 9.8 A
Fuel Heating oil or diesel
Fuel consumption max. Stage 1 NS NS 36.7 l/h
Stage 2 * 19.5 l/h 20.9 l/h
Outlet cone ø 550 mm ø 550 mm ø 3 x 500 mm
Chimney connection ø 200 mm ø 200 mm ø 300 mm
Thermostat connection standard standard standard
Dimensions L x W x H 2,400 x 800 x 1,370 mm 2,400 x 800 x 1,370 mm 3,900 x 1,200 x 2,010 mm
Mobility Fork lifter / crane
Weight 480 kg 505 kg 1,050 kg
Electricity supply Mains cable with 16 A CEE plug, 5-pole Mains cable with 16 A CEE plug, 5-pole 32 A CEE socket, 5-pole
* two-stage operation is scope of standard equipment for the ID 1000 and optionally available for the ID 1200
** without burner, in compliance with DIN 45635-01-KL 3
*** ΔT designates the increase in temperature. The air discharge temperature is calculated using ΔT + ambient air temperature. Calculation example for ID 1000 oil heating station with an ambient temperature of 20 °C: ΔT (57) + 20 = 77. The air discharge temperature in this example equals 77 °C.