High-performance electric heating units TDE 200, 300 and 400

TDE 200 TDE 300 TDE 400
Technical data TDE 200 TDE 300 TDE 400
Article number 1.410.000.150 1.410.000.155 1.410.000.160
Heating performance 40 kW (34,394 kcal) 80 kW (68,788 kcal) 120 kW (103,181 kcal)
Air flow rate max. 3,000 m³/h 6,000 m³/h 9,000 m³/h
Air pressure 600 hPa
Blow out temperature max.* 60 °C
Temperature increase (∆T) max. 60 °C
Fan radial / 1,5 kW radial / 4 kW radial / 5,5 kW
Control Eight-stage switch for air flow rate and temperature
Stufe 0 Air flow rate 3,000 m³/h 6,000 m³/h 9,000 m³/h
Temperature increase (∆T)
Stage 1 Air flow rate 3,000 m³/h 6,000 m³/h 9,000 m³/h
Temperature increase (∆T) 15 °C
Stage 2 Air flow rate 3,000 m³/h 6,000 m³/h 9,000 m³/h
Temperature increase (∆T) 28 °C
Stage3 Air flow rate 3,000 m³/h 6,000 m³/h 9,000 m³/h
Temperature increase (∆T) 40 °C
Stage 4 Air flow rate 2,000 m³/h 4,000 m³/h 6,000 m³/h
Temperature increase (∆T)
Stage 5 Air flow rate 2,000 m³/h 4,000 m³/h 6,000 m³/h
Temperature increase (∆T) 15 °C
Stage 6 Air flow rate 2,000 m³/h 4,000 m³/h 6,000 m³/h
Temperature increase (∆T) 30 °C
Stage 7 Air flow rate 2,000 m³/h 4,000 m³/h 6,000 m³/h
Temperature increase (∆T) 60 °C
Input voltage 400 V / 50 Hz
Power consumption max. 61 A (41.5 kW) 123 A (84 kW) 182 A (125.5 kW)
Fuse protection / plug 63 A / CEE 63 A, 5-pin 125 A / CEE 125 A, 5-pin 200 A / direct connection
Hose connection ø 450 mm 600 mm
Suitable for hose lengths up to 100 m 100 m 100 m
Mobility wheelable/ fork lift / crane
Sound level (distance 3 m) 75 dB (A)
76 dB (A)
78 dB (A)
Minimum cable diameter 16 mm² 50 mm² 95 mm²
Overheat protection yes
Length 1,980 mm 2,000 mm 2,300 mm
Width 800 mm 800 mm 950 mm
Height 1,300 mm 1,300 mm 1450 mm
Weight 340 kg 380 kg 540 kg
* the maximum blow out temperature for the standard model is automatically electronically limited to 60 °C .
Other models with higher blow out temperatures are available on request.