| Model |
PAC 3500 |
PAC 4400 |
| Suitable for rooms up to approx. m³ |
115 |
145 |
| Dehumidifier function |
x |
x |
| Ventilation function (fans without cooling) |
x |
x |
| Automatic function (fully automated operation) |
– |
x |
| Directive air output |
x |
x |
| Swing-Funktion |
– |
x |
| IR remote control |
x |
x |
| Electronic control panel |
x |
x |
| Microprocessor-controlled operation |
x |
x |
| 24-hour time clock |
x |
x |
| Room thermostat |
x |
x |
| Antibacterial filter – Improved air quality (washable) |
x |
x |
| Variable indoor unit fan speeds |
3 |
3 |
| Transport castors on indoor/outdoor units |
x / – |
x / – |
| Air conditioner type: |
|
|
| Mobile monoblock system |
x |
– |
| Mobile split system with snaplock coupling |
– |
x |
| Technical data: |
|
|
| Article no. |
1.210.002.100 |
1.210.000.020 |
| Suitable for rooms up to approx. |
115 m³ |
145 m³ |
| Type |
Monoblock system |
Split system |
| Cooling capacity max. 1) |
3.5 kW (11,942 Btu) |
4.2 kW (14,330 Btu) |
| Cooling medium |
Air |
Air |
| Operating range internal unit |
16 °C to 35 °C |
21 °C to 35 °C |
| Operating range external unit |
– |
21 °C to 43 °C |
| Air flow rate max. |
480 m³/h |
600 m³/h |
| Dehumidification performance max. |
2.2 l / h |
1.8 l / h |
| Fan stages |
3 |
3 and automatic |
| Input voltage |
230 V / 50 Hz |
230 V / 50 Hz |
| Power input max. |
1.29 kW |
1.38 kW |
| Current consumption / fuse protection |
5.76 A / 10 A |
6.2 A / 10 A |
| Cooling agent |
R 410A |
R 410A |
| Amount of cooling agent |
620 g |
970 g |
Sound level 2) internal unit, stage 1 / 2 / 3
(distance 3 m) |
47 / 50 / 53 dBA |
48 / 50 / 52 dBA |
| Sound level 2) external unit |
– |
51 dBA |
| Dimensions internal unit L x W x H |
400 x 510 x 855 mm |
335 x 470 x 695 mm |
| Dimensions external unit L x W x H |
– |
230 x 510 x 490 mm |
| Weight internal unit / external unit |
36.5 kg / – |
35 kg / 13 kg |
| Exhaust hose, length / ø |
1,250 mm / 125 mm |
– |
| Connecting pipe total length / usable length |
– |
3,000 mm 3) / 2,300 mm |
| 1) at 30 °C and 70 % RH: 2) Noise measurement DIN 45635 - 01 - KL3; 3) Non-extendable |